Ukufudumeza ngelanga, ngokomgaqo, sisisombululo esifanelekileyo samandla avuselelekayo kwizakhiwo. Kucocekile, kuninzi, kwaye kufumaneka simahla. Kodwa kangangamashumi eminyaka, kukho isiphene esibalulekileyo esithintele ubushushu belanga ukuba bungafikeleli kwisakhono salo esipheleleyo:ilanga alikhanyi xa lifunekaAmandla elanga afika ngobuninzi ngexesha lasemini, aze anyamalale xa imfuneko yokufudumeza ifikelela kwinqanaba eliphezulu — ngokuhlwa nasebusuku. Iintsuku ezinamafu kunye neenyanga zasebusika ziyayenza ingxaki ibe mandundu, zishiya abahlali besakhiweni bephantsi kweenkqubo zokugcina amafutha efosili.

Iindlela zokugcina ubushushu zemveli — ikakhulu iitanki zamanzi ashushu — ziye zazama ukuvala esi sikhewu, kodwa ziza nemida ebalulekileyo. Amanzi agcina ubushushu ngendlela enengqondo, oko kuthetha ukuba ubushushu bawo kufuneka bunyuke kakhulu ukuze kugcinwe amandla abalulekileyo. Oku kuthetha ukuba iitanki ezinkulu, ezinkulu ezisebenzisa indawo yokwakha exabisekileyo, zilahlekelwa bubushushu obungalindelwanga, kwaye zizisa ubushushu obuphantsi kancinci njengoko zikhupha. Kwizakhiwo ezinemigangatho emininzi kunye neendawo zokuhlala zasezidolophini apho indawo iphezulu khona, ezi nkqubo azisebenzi.

Ngoku, isisombululo esitshintshayo sivele kwiilebhu zeGlacier Coolant:izitshintshi zobushushu zokugcina ubushushu ze-finned-tube phase changeEzisebenzisa amandla obushushu angabonakaliyo kakhulu ezixhobo zokutshintsha isigaba eziphambili. Le teknoloji ichaza ngokutsha oko iinkqubo zokufudumeza zelanga zinokukufezekisa.

Isayensi Yokugcina Ubushushu Obufihlakeleyo

Intliziyo yale nto intsha ikwiGlacier CoolantI-LM-XR-53, indlela yokutshintsha isigaba eyenzelwe ukugcina nokukhupha amandla amaninzi obushushu kubushushu obulawulwa ngokuchanekileyo53°CNgokungafaniyo nezinto eziqhelekileyo ezifudumala kancinci kancinci, izinto zokutshintsha isigaba zifunxa amandla ngokutshintsha imeko yazo yomzimba — zitshintshela ekubeni ziqinileyo ziye kulwelo — kwaye ngokwenza njalo, zifunxa amandla amaninzi kakhulu ngeyunithi yobunzima kunayo nayiphi na indlela yokugcina enengqondo.

Amanani abalisa ibali elinomtsalane. I-Glacier Coolant LM-XR-53 inika amandla obushushu afihlakeleyo268.9 J/gUkubeka oku ngendlela eyiyo, amandla afunekayo ukunyibilikisa ikhilogram enye yale nto alingana nokufudumeza ubunzima obufanayo bamanzi ngaphezulu kwama-64 degrees Celsius. Olu xinano lwamandla lungaqhelekanga yilo olubangela ukuba kube nokwenzeka ukugcina ubushushu obuncinci nobusebenza kakuhle.

268.9 J/g
Umthamo wobushushu obufihlakeleyo
53°C
Ubushushu boTshintsho lweSigaba
+ 30%
Ukuphuculwa kweCandelo leSolar

Ubunjineli beFinned-Tube Advantage

Ukukhanya kwenkqubo yeGlacier Coolant kufikelela ngaphaya kwezinto zokutshintsha isigaba ngokwazo — kukudityaniswaI-LM-XR-53kwiuyilo lwe-finned-tube heat exchangeroluvula amandla apheleleyo okusebenza. Uyilo lufaka i-PCM kwisixhobo esincinci sokutshintsha ubushushu esineendawo ezinde zamaphiko eziyandisa kakhulu indawo yokudlulisa ubushushu phakathi kolwelo lokudlulisa ubushushu olujikelezayo kunye nendawo yokugcina.

Olu khetho loyilo aluxhomekekanga. Uphando olwenziwe liqela lobunjineli beGlacier Coolant luchaze ngokungqongqo ulwalamano phakathi kweeparamitha zokusebenza kunye nokusebenza kwenkqubo. Ezi ziphumo ziyafundisa kwaye ziyasebenza kubayili beenkqubo:

“Kwiqondo lobushushu lokungena elingama-70°C, umthamo wotshintshiselwano lobushushu uwonke unyuka ngama-55.59% xa kuthelekiswa nokusebenza kwama-60°C. Ukuphinda kabini isantya sokuhamba ukusuka kwi-0.5 m/s ukuya kwi-1.5 m/s kunokuphantse kuphindwe kabini izinga lokudluliselwa kobushushu — kunika abaqhubi beenkqubo ulawulo oluchanekileyo kwimveliso yobushushu.”
Ipharamitha yokusebenza Isiseko Iphuculwe Inzuzo yokusebenza
Ubushushu bamanzi okungena 60°C 70°C +55.59%utshintshiselwano lobushushu
Isantya Sokuhamba 0.5 m/s 1.5 m/s Ukuya kuthi ga kwi-100%ukunyuka kokudluliselwa kobushushu
Inxalenye yeSolar (xa kuthelekiswa netanki enye) Isiseko Kunye nendawo yokugcina i-PCM + 30%uphuculo
Inkqubo yeNyathelo Itanki eqhelekileyo Isitshintshi sobushushu se-PCM -74%ukunciphisa indawo

Ukukhupha i-Isothermal: Inzuzo Efihliweyo

Enye yezona nzuzo zingaxatyiswanga kakhulu zokugcina ubushushu obutshintsha isigaba kukubaukukhululwa kobushushu obungashushuXa iGlacier CoolantI-LM-XR-53ikhupha amandla ayo agciniweyo, ikwenza oko kubushushu obuphantse bube yi-53°C. Oku kwahlukile kakhulu kwindawo yokugcina amanzi, apho ubushushu bokukhupha buncipha kancinci njengoko itanki iphola.

Kwizicelo zokufudumeza izakhiwo, le ndlela yokuziphatha ye-isothermal iguqulela ekubeni yintuthuzelo ephezulu kunye nokusebenza kakuhle kwenkqubo. Iiradiyatha kunye neenkqubo zokufudumeza ezingaphantsi komgangatho zifumana ubushushu obuhambelanayo kulo lonke umjikelo wokukhupha, nto leyo esusa imfuneko yeevalvu zokuxuba ezintsonkothileyo kunye nolawulo lokuhlawula ubushushu. Iinkqubo zepompo yobushushu, xa zidibene ne-PCM storage, zinokusebenza kwindawo yazo yokusebenza kakuhle endaweni yokunyuka nokuhla ukuze zihambelane neemfuno eziguquguqukayo.

Ukusuka Kwizinga Lekhaya Ukuya KwiSithili

I-Glacier Coolant finned-tube PCM heat exchanger iyakwazi ukwandiswa ngokwendalo. Kwizindlu ngazinye, iyunithi encinci edityaniswe nee-solar thermal collectors eziphezu kophahla inokubonelela ngobuninzi beendawo zokufudumeza kunye neemfuno zamanzi ashushu asekhaya unyaka wonke. Ukuncipha kwe-74% kwi-footprint xa kuthelekiswa nokugcinwa kwamanzi okulinganayo kuthetha ukuba ezi nkqubo zinokufakwa kumagumbi ombane, amagumbi angaphantsi komhlaba, okanye zifakwe nakwi-facade yesakhiwo.

Kwisikali sokufudumeza sesithili, uluhlu lwee-PCM heat exchangers zinokuthintela ukuguquguquka kwamasimi amakhulu obushushu belanga, zinciphise ukuveliswa kobushushu ngenxa yemfuno yobushushu kwiindawo zonke. Oku kudibanisa kubaluleke kakhulu ekusebenzeni kakuhle koqoqosho lokufudumeza kwesithili selanga, njengoko kuvumela abaqhubi ukuba balinganise amasimi okuqokelela amandla ngonyaka wonke kunokuba banciphise imfuno ekhawulezileyo.

Impembelelo Yokunciphisa Ikhabhoni

Izakhiwo zixabisa malungaI-40% yokukhutshwa kwe-CO2 okunxulumene namandla kwihlabathi liphela, apho ukufudumeza indawo kumela ukusetyenziswa okukhulu. E-China kuphela, ukufudumeza izakhiwo kudla ngaphezulu kweetoni ezingama-200 ezigidi zamalahle ngonyaka. Ngokuvumela iinkqubo zobushushu belanga ukuba zihlangabezane ngokuthembekileyo nenxalenye ephezulu kakhulu yemfuno yokufudumeza, itekhnoloji yokugcina i-Glacier Coolant PCM isusa ngokuthe ngqo ukusetyenziswa kwepetroli yeefosili ngomlinganiselo.

Cinga ngesakhiwo esiqhelekileyo sokuhlala esiphakathi esineeyunithi zeflethi ezingama-50. Inkqubo yobushushu belanga edibene neGlacier Coolant PCM yokugcina inokunciphisa ukusetyenziswa kwegesi yendalo ukufudumeza ngama-60-70% xa kuthelekiswa nenkqubo eqhelekileyo yebhoyila kuphela. Kwiminyaka engama-20 yobomi benkqubo, oku kuthetha ukuba ngamakhulu eetoni zokukhutshwa kwe-CO2 okuthintelweyo kwisakhiwo ngasinye.

Izinto ezibalulekileyo ekufuneka ziqwalaselwe

  • Isipholisi seGlacierI-LM-XR-53inika ubushushu obufihlakeleyo obuyi-268.9 J/g kubushushu obuzinzileyo bokutshintsha kwesigaba obuyi-53°C
  • Uyilo lwe-Finned-tube heat exchanger luphucula indawo yomphezulu wokudlulisa ubushushu ukuze kutshajwe kwaye kukhutshwe ngokukhawuleza
  • Inxalenye yelanga iphucuka malunga nama-30% xa kuthelekiswa neenkqubo zokugcina amanzi zetanki enye eziqhelekileyo
  • Umlinganiselo wenkqubo uncitshiswe ngama-74%, nto leyo evumela ukufakwa kwezakhiwo zasezidolophini ezixineneyo
  • Ukukhupha i-isothermal kwi-53°C kuqinisekisa intuthuzelo yokufudumeza rhoqo ngaphandle kokuwohloka kobushushu
  • Isantya sokuhamba kunye nobushushu bokungena zibonelela ngezixhobo zokulawula ezichanekileyo zokuphucula imveliso yenkqubo
  • Ingandiswa ukusuka kumakhaya osapho olunye ukuya kuthungelwano lokufudumeza lwesithili, ixhasa iinjongo zesatifikethi sesakhiwo esiluhlaza

Indlela Engaphambili

Njengoko oorhulumente kwihlabathi liphela beqinisa iikhowudi zamandla okwakha kwaye besandisa imiyalelo yokufudumeza evuselelekayo, imfuno yokugcina ubushushu obuncinci nobusebenzayo iya kukhula ngakumbi. I-Energy Performance of Buildings Directive (EPBD) ehlaziyiweyo ye-European Union kunye nokuqhubela phambili kweTshayina kwizakhiwo zamandla eziphantse zibe zero zombini zenza ulawulo oluqinileyo lwetekhnoloji efana ne-Glacier Coolant PCM heat exchanger.

Itekhnoloji ilungile. Uqoqosho luyanyanzelisa. Imfuneko yokusingqongileyo ingxamisekile. Kubakhi bezakhiwo, abaphuhlisi bezakhiwo, kunye neenjineli ze-HVAC abafuna ukubonelela ngezisombululo zokufudumeza ezizinzileyo ngokwenene, indawo yokugcina ubushushu yokutshintsha kwesigaba se-finned-tube ayimeli nje uphuculo oluqhubekayo, kodwa utshintsho oluncinci kwinto enokwenzeka. Ukufudumeza kwelanga akusafuneki kube ngumhlobo wemozulu efanelekileyo - kunye ne-Glacier Coolant cold media, liqabane elithembekileyo, unyaka wonke ekutshintsheleni kwindawo eyakhiwe ngekhabhoni ephantsi.